Users Guide
• IPMI Settings
• VLAN Settings
6 Click Back, click Finish, and then click Yes.
The network information is saved and the system reboots.
Related link
Network settings
Common settings
IPv4 settings
IPv6 settings
IPMI settings
VLAN settings
Network settings
To congure the Network Settings:
NOTE: For information about the options, see the
iDRAC Settings Utility Online Help
.
1 Under Enable NIC, select the Enabled option.
2 From the NIC Selection drop-down menu, select one of the following ports based on the network requirement:
• Dedicated — Enables the remote access device to use the dedicated network interface available on the Remote Access Controller
(RAC). This interface is not shared with the host operating system and routes the management trac to a separate physical
network, enabling it to be separated from the application trac.
This option implies that iDRAC's dedicated network port routes its trac separately from the server's LOM or NIC ports. About
managing network trac, the Dedicated option allows iDRAC to be assigned an IP address from the same subnet or dierent
subnet in comparison to the IP addresses assigned to the Host LOM or NICs.
NOTE
: In blade servers, the Dedicated option is displayed as Chassis (Dedicated).
• LOM1
• LOM2
• LOM3
• LOM4
NOTE
: In the case of rack and tower servers, two LOM options (LOM1 and LOM2) or all four LOM options are available
depending on the server model. In blade servers with two NDC ports, two LOM options (LOM1 and LOM2) are available
and on server with four NDC ports, all four LOM options are available.
NOTE: Shared LOM is not supported on the following bNDCs if they are used in a full — height server with two NDCs
because they do not support hardware arbitration:
• Intel 2P X520–k bNDC 10 G
• Emulex OCM14102–N6–D bNDC 10 Gb
• Emulex OCm14102-U4-D bNDC 10 Gb
• Emulex OCm14102-U2-D bNDC 10 Gb
• QLogic QMD8262–k DP bNDC 10 G
3 From the Failover Network drop-down menu, select one of the remaining LOMs. If a network fails, the trac is routed through the
failover network.
For example, to route the iDRAC network trac through LOM2 when LOM1 is down, select LOM1 for NIC Selection and LOM2 for
Failover Network.
NOTE
: If you have selected Dedicated in NIC Selection drop-down menu, the option is grayed-out.
Setting up managed system and management station 43