Users Guide

Conguring power supply options using iDRAC settings utility
To congure the power supply options:
1 In iDRAC Settings utility, go to Power Conguration.
NOTE: The Power Conguration link is available only if the server power supply unit supports power
monitoring.
The iDRAC Settings Power Conguration page is displayed.
2 Under Power Supply Options:
Enable or disable power supply redundancy.
Enable or disable hot spare.
Set the primary power supply unit.
Enable or disable power factor correction. For more information about the options, see the iDRAC Settings Utility Online Help.
3 Click Back, click Finish, and then click Yes.
The power supply options are congured.
Enabling or disabling power button
To enable or disable the power button on the managed system:
1 In iDRAC Settings utility, go to Front Panel Security.
The iDRAC Settings Front Panel Security page is displayed.
2 Select Enabled to enable the power button or Disabled to disable it.
3 Click Back, click Finish, and then click Yes.
The settings are saved.
Monitoring and managing power
185