Users Guide

Setting event actions using web interface
To set an event action:
1 In iDRAC Web interface, go to Overview > Server > Alerts. The Alerts page is displayed.
2 Under Alerts Results, from the Actions drop-down menu, for each event select an action:
Reboot
Power Cycle
Power O
No Action
3 Click Apply.
The setting is saved.
Setting event actions using RACADM
To congure an event action, use the eventlters command. For more information, see the iDRAC RACADM Command Line Interface
Reference Guide available at dell.com/idracmanuals.
Conguring email alert, SNMP trap, or IPMI trap
settings
The management station uses Simple Network Management Protocol (SNMP) and Intelligent Platform Management Interface (IPMI) traps
to receive data from iDRAC. For systems with large number of nodes, it may not be ecient for a management station to poll each iDRAC
for every condition that may occur. For example, event traps can help a management station with load balancing between nodes or by
issuing an alert if an authentication failure occurs. SNMP v1, v2, and v3 formats are supported.
You can congure the IPv4 and IPv6 alert destinations, email settings, and SMTP server settings, and test these settings. You can also
specify the SNMP v3 user to whom you want to send the SNMP traps.
Before conguring the email, SNMP, or IPMI trap settings, make sure that:
You have Congure RAC permission.
You have congured the event lters.
Related link
Conguring IP alert destinations
Conguring email alert settings
Conguring IP alert destinations
You can congure the IPv6 or IPv4 addresses to receive the IPMI alerts or SNMP traps.
For information about the iDRAC MIBs required to monitor the servers using SNMP, see the SNMP Reference Guide available at dell.com/
support/manuals.
Conguring
iDRAC to send alerts 167