Users Guide
Conguring iDRAC to use SOL
You can specify the SOL settings in iDRAC using Web interface, RACADM, or iDRAC Settings utility.
Conguring iDRAC to use SOL using iDRAC web interface
To congure IPMI Serial over LAN (SOL):
1 In the iDRAC Web interface, go to Overview > iDRAC Settings > Network > Serial Over LAN.
The Serial over LAN page is displayed.
2 Enable SOL, specify the values, and click Apply.
The IPMI SOL settings are congured.
3 To set the character accumulate interval and the character send threshold, select Advanced Settings.
The Serial Over LAN Advanced Settings page is displayed.
4 Specify the values for the attributes and click Apply.
The IPMI SOL advanced settings are congured. These values help to improve the performance.
For information about the options, see the iDRAC Online Help.
Conguring iDRAC to use SOL using RACADM
To congure IPMI Serial over LAN (SOL):
1 Enable IPMI Serial over LAN using the command.
racadm set iDRAC.IPMISol.Enable 1
2 Update the IPMI SOL minimum privilege level using the command.
racadm set iDRAC.IPMISol.MinPrivilege <level>
Parameter
Privilege level
<level> = 2 User
<level> = 3 Operator
<level> = 4 Administrator
NOTE: The IPMI SOL minimum privilege level determines the minimum privilege to activate IPMI SOL. For more
information, see the IPMI 2.0 specication.
3 Update the IPMI SOL baud rate using the command.
racadm set iDRAC.IPMISol.BaudRate <baud_rate>
NOTE
: To redirect the serial console over LAN, make sure that the SOL baud rate is identical to the managed system’s
baud rate.
Parameter Allowed values (in bps)
<baud_rate> 9600, 19200, 38400, 57600, and 115200.
4 Enable SOL for each user using the command.
racadm set iDRAC.Users.<id>.SolEnable 2
Parameter
Description
<id> Unique ID of the user
Setting up iDRAC communication 121