Release Notes

iDRAC6 v2.92.00 6
Issue 5
Description
After adding or removing new hardware, System Inventory page may not update the changes automatically.
This is because inventory data collected during manufacturing process may not be updated with new
changes.
Resolution
During BIOS POST, select <Ctrl+E> and enable Collect System Inventory on reboot. Save and exit from
<Ctrl+E> option and then reboot the system to collect new system inventory. After the inventory is collected,
the System Inventory page displays the correct Hardware and software inventory data.
Issue 6
Description
In the System Details page, the Virtual MAC field is not populated if system inventory is not run from the
iDRAC web interface before accessing this page. This is because the inventory data may not be available for
Virtual MAC to display.
Resolution
In the iDRAC web interface, click System Inventory tab. Make sure that inventory data is displayed on the
System Inventory page. After the data is loaded, click the System Details tab. The Virtual MAC field
displays the inventory data, if the system supports this feature.
Versions/Systems affected
All supported systems.
Issue 7
Description
When you access the iDRAC web interface in IPv6 network with Mozilla Firefox 4.0 or later and accept the
CSR certificate, it displays an error message, "An error has occurred during a connection to <server
certificate info>, Peer certificate issuer has been marked as not trusted by the user. (Error code:
sec_error_untrusted_issuer)."
Resolution
Create a certificate request and issue it to a trusted domain. Register it to a domain DNS server. Use a trusted
domain name, instead of the IPv6 address.
Versions/Systems affected
All supported systems.
Issue 8
Description
iDRAC browse a page that uses JavaScript functions to retrieve page data, the progress bar in Internet
Explorer may not always be accurate.
Resolution
N/A
Versions/Systems affected
All supported systems.