Release Notes
Issue 4
Description
If you add more than 800 work notes, the web interface may take additional time to load the page. This is due to huge
amount of data that needs to be transacted between the web interface and iDRAC6. The newly added work notes may
not be displayed after the page is loaded.
Resolution
Click Refresh.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 5
Description
After adding or removing new hardware, System Inventory page may not update the changes automatically. This is
because inventory data collected during manufacturing process may not be updated with new changes.
Resolution
During BIOS POST, select <Ctrl+E> and enable Collect System Inventory on reboot. Save and exit from <Ctrl+E>
option and then reboot the system to collect new system inventory. After the inventory is collected, the System
Inventory page displays the correct Hardware and software inventory data.
Issue 6
Description
In the System Details page, the Virtual MAC field is not populated if system inventory is not run from the iDRAC web
interface before accessing this page. This is because the inventory data may not be available for Virtual MAC to
display.
Resolution
In the iDRAC web interface, click System Inventory tab. Make sure that inventory data is displayed on the System
Inventory page. After the data is loaded, click the System Details tab. The Virtual MAC field displays the inventory
data, if the system supports this feature.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 7
Description
When you access the iDRAC web interface in IPv6 network with Mozilla Firefox 4.0 or later and accept the CSR
certificate, it displays an error message, "An error has occurred during a connection to <server certificate info>, Peer
certificate issuer has been marked as not trusted by the user. (Error code: sec_error_untrusted_issuer)."
Resolution
Create a certificate request and issue it to a trusted domain. Register it to a domain DNS server. Use a trusted domain
name, instead of the IPv6 address.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 8
Description
iDRAC browse a page that uses JavaScript functions to retrieve page data, the progress bar in Internet Explorer may not
always be accurate.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.