Release Notes

Issue 10
Description
When the Certificate Authority (CA) is enabled, the Domain Controller (DC) is specified as FQDN and
Global Catalog (GC) as IP address, the authentication using Test Settings fails and normal login succeeds.
The expected behavior is the authentication using Test Settings must succeed by using DC FQDN.
Resolution
Specify the FQDN for GC.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 11
Description
SSH server takes more time to establish a connection from putty client.
Resolution
For improving the performance, change the order of the key exchange algorithm in Putty SSH
configuration:
1. Open Putty.
2. Expand SSH tab.
3. Click Kex.
4. Change the order in the Algorithm selection policy window.
5. Connect to the SSH server. The connection is established.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 12:
Description
iDRAC6 firmware update is unsuccessful when using local RACADM on Microsoft Windows 2008 R2 (64-
bit) operating system.
Resolution
iDRAC6 needs a 64-bit executable to perform the update. Perform the firmware update using other
interfaces such as Web interface, remote RACADM, or perform firmware update using DUP.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 13:
Description
In a system with Windows 2012 Spring Update 14 edition and Dell OpenManage 7.4, the operating
system name may not appear on the iDRAC6 Web interface and RACADM. This is an intermittent issue.
Resolution
View the operating system name from the Dell OpenManage Server Administrator installed on the host.
Versions/Systems Affected