Users Guide
3. 在"Startup and Recovery"( 启动和恢复 ) 下,单击"Settings"(设置)。
4. 取消选择" 自动重新引导"复选框。
5. 单击"OK"(确定)两次。
配置平台事件
平台事件配置提供了用于配置远程访问设备针对某些事件信息执行所选操作的机制。这些操作包括重新引导、关机后再开机、关机以及触发警报(平台事件陷阱 [PET] 和/或电子邮件)。
可筛选的平台事件包括以下:
l Fan Critical Assert Filter
l Battery Warning Assert Filter
l Battery Critical Assert Filter
l Voltage Critical Assert Filter
l Temperature Warning Assert Filter
l Temperature Critical Assert Filter
l Intrusion Critical Assert Filter
l Redundancy Degraded Filter
l Redundancy Lost Filter
l Processor Warning Assert Filter
l Processor Critical Assert Filter
l Processor AbsentCritical Assert Filter
l Power Supply Warning Assert Filter
l Power Supply Critical Assert Filter
l Power Supply AbsentCritical Assert Filter
l Event Log Critical Assert Filter
l Watchdog Critical Assert Filter
l System Power Warning Assert Filter
l System Power Critical Assert Filter
l Removable Flash Media Informational Assert Filter
l Removable Flash Media Absent Informational Assert Filter
l Removable Flash Media Critical Assert Filter
l Removable Flash Media Warning Assert Filter
出现平台事件时(例如,风扇探测器故障),会生成系统事件并在系统事件日志 (SEL) 中记录。如果该事件匹配基于 Web 的界面中平台事件筛选器列表中的平台事件筛选器 (PEF),并且
已配置该筛选器生成警报(PET 或电子邮件),则会将 PET 或电子邮件警报发送到一个或多个配置目标。
如果还将同一平台事件筛选器配置为执行操作(比如重新引导系统),则将执行该操作。
配置平台事件筛选器 (PEF)
在配置平台事件陷阱或电子邮件警报设置之前,配置平台事件筛选器。
使用基于 Web 的界面配置 PEF
有关详细信息,请参阅"配置平台事件筛选器 (PEF)"。
使用 RACADM CLI 配置 PEF
1. 启用 PEF。
打开命令提示符,键入以下命令并按 <Enter>:
racadm config -g cfgIpmiPef -o cfgIpmiPefEnable -i 1 1