Users Guide

Embedded NIC MAC Addresses:
NIC1 Ethernet = 00:24:e8:2e:c5:cb
iSCSI = 00:24:e8:2e:c5:cc
NIC2 Ethernet = 00:24:e8:2e:c5:cd
iSCSI = 00:24:e8:2e:c5:ce
NIC3 Ethernet = 00:24:e8:2e:c5:cf
iSCSI = 00:24:e8:2e:c5:d0
NIC4 Ethernet = 00:24:e8:2e:c5:d1
iSCSI = 00:24:e8:2e:c5:d2
Watchdog Information:
Recovery Action = None
Present countdown value = 15 seconds
Initial countdown value = 15 seconds
示例
l racadm getsysinfo -A -s
"System Information:" "PowerEdge 2900" "A08" "1.0" "EF23VQ-0023" "Hostname"
"Microsoft Windows 2000 version 5.0, Build Number 2195, Service Pack 2" "ON"
l racadm getsysinfo -w -s
System Information:
SystemModel=PowerEdge2900
SystemBIOSVersion=0.2.3
BMCFirmwareVersion=0.17
ServiceTag=48192
HostName=racdev103
OSName=MicrosoftWindowsServer2003
PowerStatus=OFF
Watchdog Information:
RecoveryAction=None
Presentcountdownvalue=0seconds
Initialcountdownvalue=0seconds
限制
只有 Managed System 上装有 Dell™OpenManage™ServerAdministrator时,getsysinfo 输出中的“Hostname(主机名)和“OS Name(操作系统名称)字段才会显示
准确的信息。如果没有安装,这些字段可能为空白或不准确。
getractime
A-16 说明了 getractime 子命令。
A-16.getractime
提要
注:要使用此命令,必须具有Login to iDRAC(登iDRAC权限。
子命令
getractime
显示 Remote Access Controller 的当前时间。