Release Notes
file:///T|/htdocs/SOFTWARE/smdrac3/idrac/idrac12mono/en/readme/readme.txt[10/26/2012 1:33:29 PM]
ISO image present in the ESX Service Console can be made accessible to
the VM. Avoid this issue by creating an image of the floppy or CD-ROM
and copying it to the Service Console.
* Using the VMCLI tool from within a system running Windows Vista
To use VMCLI from within a system running Windows Vista -
The user has to start up the 'cmd' with 'Run as Administrator'.
(VMCLI requires that the user has 'administrator' privileges
when it is used.)
Note: User can log in as a non-admin user, but when using VMCLI,
the user has to start 'cmd' with 'Run as Administrator' privilege
thereby giving them admin privileges to enable using VMCLI.
* Uploading images from multiple management systems to the virtual
flash at the same time has to be avoided in order to prevent image
corruption.
* The name of the firmware image file for iDRAC6 is firmimg.d6
* If the network cable to iDRAC6 is disconnected and then connected
again, iDRAC6 will not negotiate a new IP address until the current
lease expires.
* Remote Racadm and VMCLI utilities are not supported with IPv6
in this release.
* If iDRAC6 firmware update is interrupted for any reason, a wait of
up to 30 minutes may be required before another firmware update
operation is again allowed.
* The Diagnostic tab on the GUI page is not operational if iDRAC6
Enterprise card is not installed.
* Enabling Virtual Flash from iDRAC6 Configuration Utility will not
take effect if the SD card is not formatted. Format the SD card
from iDRAC6 GUI or using "racadm vmkey reset" command before
enabling it.
* In SM-CLP start or stop on the target /system1/ sp1/adsvc1 displays
an error “*-* yyerror: syntax error, unexpected ZTOK_PARAMVALUE,
expecting XTOK_VALUE or XTOK_VALUEARRAY or XTOK_VALUEREFERENCE”
and hangs the telnet/ssh session. It recovers only when the session
times out or is restarted. This target is not supported with
iDRAC6 firmware version 1.20.
* You must close an open POST boot capture log video before you play
another one. You cannot play two logs simultaneously.
* The status for System Board Riser1 Pres and System Board Riser2
Pres sensors is reported incorrectly as unknown instead of good