Users Guide

Advanced Configuration of the iDRAC6 99
3
Next to
Connect using:
, select the COM port on the management station
(for example, COM2) to which you have connected the DB-9 null modem
cable and click
OK
.
4
Configure the COM port settings as shown in Table 5-7.
5
Click
OK
.
6
Click
File
Properties
, and then click the
Settings
tab.
7
Set the
Telnet terminal ID:
to
ANSI
.
8
Click
Terminal Setup
and set
Screen Rows
to
26
.
9
Set
Columns
to
80
and click
OK
.
Configuring Serial and Terminal Modes
Configuring IPMI and iDRAC6 Serial
1
Expand the
System
tree and click
Remote Access
.
2
Click the
Configuration
tab and then click
Serial
.
3
Configure the IPMI serial settings.
See Table 5-8 for description of the IPMI serial settings.
4
Configure the iDRAC6 serial settings.
See Table 5-9 for description of the iDRAC6 serial settings.
5
Click
Apply Changes
.
6
Click the appropriate
Serial Configuration
page button to continue.
See Table 5-10 for description of the serial configuration page settings.
Table 5-7. Management Station COM Port Settings
Setting Description Required Setting
Bits per second 57600
Data bits 8
Parity None
Stop bits 1
Flow control Hardware