Users Guide

60 Configuring the iDRAC6 Using the Web Interface
When a platform event occurs (for example, a battery warning assert),
a system event is generated and recorded in the System Event Log (SEL).
If this event matches a platform event filter (PEF) that is enabled and you
have configured the filter to generate an alert (PET or e-mail), then a PET or
e-mail alert is sent to one or more configured destinations.
If the same platform event filter is also configured to perform an action
(such as rebooting the system), the action is performed.
Configuring Platform Event Filters (PEF)
NOTE: Configure platform event filters before you configure the platform event
traps or e-mail alert settings.
1
Log in to the remote system using a supported Web browser.
See "Accessing the Web Interface."
2
Click
System
Alert Management
Platform Events
.
3
In the first table, select the
Enable Platform Event Filter Alerts
checkbox
and then click
Apply Changes
.
NOTE: Enable Platform Event Filter Alerts must be enabled for an alert to be
sent to any valid, configured destination (PET or e-mail).
4
In the next table,
Platform Event Filters List
, click the filter that you want
to configure.
5
In the
Set Platform Events
page, select the appropriate
Shutdown
Action
or select
None
.
6
Select or deselect
Generate Alert
to enable or disable this action.
NOTE: Generate Alert must be enabled for an alert to be sent to any valid,
configured destination (PET or e-mail).
15 Power Supply Absent
16 Event Log Critical Assert
17 Watchdog Critical Assert
18 System Power Warning Assert
19 System Power Critical Assert
Table 4-10. Platform Event Filters
Index Platform Event (continued)