Users Guide
224 Configuring Intelligent Platform Management Interface (IPMI)
Using the IPMI Remote Access Serial Interface
In the IPMI serial interface, the following modes are available:
•
IPMI terminal mode
— Supports ASCII commands that are submitted
from a serial terminal. The command set has a limited number of
commands (including power control) and supports raw IPMI commands
that are entered as hexadecimal ASCII characters.
•
IPMI basic mode
— Supports a binary interface for program access,
such as the IPMI shell (IPMISH) that is included with the Baseboard
Management Utility (BMU).
To configure the IPMI mode using RACADM:
1
Disable the RAC serial interface.
At the command prompt, type:
racadm config -g cfgSerial -o
cfgSerialConsoleEnable 0
2
Enable the appropriate IPMI mode.
For example, at the command prompt, type:
racadm config -g cfgIpmiSerial -o
cfgIpmiSerialConnectionMode
<
0
or
1
>
See "iDRAC6 Property Database Group and Object Definitions" for more
information.
Configuring Serial Over LAN Using the
Web-Based Interface
For detailed information, see "Configuring IPMI."
NOTE: You can use Serial Over LAN with the following Dell OpenManage tools:
SOLProxy and IPMItool. For more information, see the Dell OpenManage
Baseboard Management Controller Utilities User’s Guide at
support.dell.com\manuals.