Users Guide

100 Advanced Configuration of the iDRAC6
Table 5-8. IPMI Serial Settings
Setting Description
Connection Mode
Setting
Direct Connect Basic Mode - IPMI Serial Basic Mode
Direct Connect Terminal Mode - IPMI Serial Terminal
Mode
Baud Rate
Sets the data speed rate. Select
9600 bps
,
19.2 kbps
,
57.6 kbps
, or
115.2 kbps
.
Flow Control
None — Hardware Flow Control Off
RTS/CTS — Hardware Flow Control On
Channel Privilege
Level Limit
Administrator
•Operator
•User
Table 5-9. iDRAC6 Serial Settings
Setting Description
Enabled Enables or disables the iDRAC6 serial console. Checked=
Enabled; Unchecked=Disabled
Timeout The maximum number of seconds of line idle time before the
line is disconnected. The range is 60 to 1920 seconds. Default
is 300 seconds. Use 0 seconds to disable the Timeout feature.
Redirect Enabled Enables or disables Console Redirection. Checked=Enabled;
Unchecked=Disabled
Baud Rate The data speed on the external serial port. Values are 9600
bps, 28.8 kbps, 57.6 kbps, and 115.2 kbps. Default is
57.6 kbps.
Escape Key Specifies the <Esc> key. The default are the ^\ characters.
History Buffer Size The size of the serial history buffer, which holds the last
characters written to the console. The maximum and default
= 8192 characters.
Login Command The iDRAC6 command line to be executed upon valid login.