Release Notes

iDRAC6 v3.85.03 9
Versions/Systems affected
All iDRAC6 supported PowerEdge systems.
Issue 17
Description
Accessing the iDRAC virtual console displays UNKNOWN publisher name message during certificate download.
Resolution
Add the iDRAC certificate. To do so, right-click on the right corner of iDRAC web Interface URL and import the
certificate.
Versions/Systems affected
All iDRAC6 supported PowerEdge systems.
Issue 18
Description
Power monitoring graph is not visible in iDRAC web interface with Internet Explorer 9 and 10 browsers.
Resolution:
Use compatibility mode in browser settings.
Versions/Systems affected
All iDRAC6 supported PowerEdge systems.
Issue 19
Description
The SD sensor states remain unchanged when the "Internal SD Card Port" BIOS option is toggled
Resolution
Upgrade to the latest supported BIOS for PowerEdge M910.
Versions/Systems affected
All iDRAC6 supported PowerEdge M910 systems.
Issue 20
Description
On the 11th generation of PowerEdge blade servers running Microsoft Windows Server 2012 R2 and Dell
OpenManage 7.4, the operating system name may not appear on the iDRAC6 GUI or the RACADM CLI interface.
This is an intermittent issue.
Resolution
View the operating system name using the Dell OpenManage Server Administrator installed on the host system.
Versions/Systems affected
All iDRAC6 supported PowerEdge systems.
Issue 21
Description
On PowerEdge modular servers with iDRAC6 version 3.75, the web GUI is inaccessible when the SSL encryption
strength is set to
168-bit or higher or 256-bit or higher and firmware is downgraded to iDRAC6 version 3.65 or
lower. However, the other interfaces are functional.
Resolution
Perform the following steps:
1. Launch the iDRAC GUI.
2. Navigate to iDRAC Settings-> Network/Security-> Services page.