Release Notes
To do this:
1.
Go to
System
->
Virtual Console/Media
->
Configuration
.
2.
Set the
Attach Virtual Medi
a option to
Detach
and click
Apply
.
3.
Set the
Attach Virtual Media
option to
Attach
and click
Apply
.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 6:
Description
The racresetcfg command in RACADM restores all properties to their default values except cfgDNSRacName in the
cfgLanNetworking group.
Resolution
Not applicable.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 7:
Description
When using a configuration file with RACADM to configure iDRAC6, changing objects that affect the network
connection stops the rest of the configuration file from taking effect.
Resolution
Not applicable.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 8:
Description
Using the iDRAC web interface to shut down the XenServer operating system by selecting Graceful Shutdown does not
shut down the server.
Resolution
It is recommended that you use the shutdown menu option in the XenServer console or in the XenCenter management
GUI.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 9:
Description
TFTP firmware update from local RACADM does not work after a racresetcfg or if IPv6 addresses are used.
Resolution
Use the firmware RACADM for TFTP firmware update.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 10:
Description
When using the Virtual Console that uses the Java plug-in with attached Virtual Media, occasionally when
disconnecting the Virtual Media, the console also closes unexpectedly.