Release Notes

Known Issues
Issue 1
Description
When the JRE is configured to verify the certificate against a Certificate Revocation List (CRL) and/or online
certificate validation the certificate validation may sometimes fail. This is because the Certificate Authority (CA) that
issued the certificate is not accessible due to connectivity problems or is not responding in a timely manner.
Resolution
Wait and retry at a later time.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 2:
Description
Remote Services: When using TFTP to download an ISO image to the vFlash, if the image exceeds the free space on
vFlash, an error message is not generated. However, subsequent operations on the ISO fails.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 3:
Description
If you run Dell Update Packages (DUPs) when vFlash is in-use, the vFlash is disconnected and reconnected. If a write
operation is in-progress, this action can corrupt the vFlash contents.
Resolution
Re-initalize the vFlash SD card.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 4:
Description
In Internet Explorer 7.0, if you launch the iDRAC6 Virtual Console when several tabs are open, all the tabs are hidden
while only the Virtual Console opens. If the tab warning is turned off and you close the Virtual Console, all the tabs
and the browser close without warning.
Resolution
To prevent this, go to Internet Properties- > Tabs-> Settings and select the Warn me when closing multiple tabs
option.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 5:
Description
If a Virtual Media drive is disconnected using the OS eject option, then the drive may not be available until the
operating system re-enumerates the USB devices.
Resolution
For the operating system to auto-detect the Virtual Media drive, the iDRAC6 Virtual Media device can be reattached.