Issue 20:
Description
On the 11th generation of PowerEdge blade servers running Microsoft Windows Server 2012 R2 and Dell
OpenManage 7.4, the operating system name may not appear on the iDRAC6 GUI or the RACADM CLI interface.
This is an intermittent issue.
Resolution
View the operating system name using the Dell OpenManage Server Administrator installed on the host system.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 21:
Description
On PowerEdge modular servers with iDRAC6 version 3.75, the web GUI is inaccessible when the SSL encryption
strength is set to 168-bit or higher or 256-bit or higher and firmware is downgraded to iDRAC6 version 3.65 or
lower. However, the other interfaces are functional.
Resolution
Perform the following steps:
1. Launch the iDRAC GUI.
2. Navigate to iDRAC Settings-> Network/Security-> Services page.
3. Set SSL Encryption to Auto-Negotiate or 128-bit or higher.
The browser session is terminated.
4. Launch a new browser session and perform the downgrade.
You can also run the following RACADM command and perform the downgrade:
racadm sslencryptionstrength set 0 (or 1)
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 23:
Description
Incorrect values listed as Legal Values and Default value for the cfgLdapRoleGroupPRivelege command in the
iDRAC6 Enterprise for Blade Servers Version 3.5 RACADM Reference Guide.
Resolution
The LDAP Role Group Privilege value may vary between 0x00000000 and 0x000001ff. The default value is 0x00.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 24:
Description
After configuring the extended schema login, there is a possibility that the login through the extended schema may fail.
This issue may occur if the Active Directory user does not have Administrator privileges.
Resolution
On Kerberos, add “Domain controllers” and “Domain admins”.