Release Notes

Issue 13
Description
On few Windows operating systems, under certain conditions, the iDRAC
ivmcli.exe
fails. This is due to run-time
components of Visual C++(R) Libraries (VC++ 2008 redistributable package) required to run applications that are not
available.
Resolution
Download and install Microsoft Visual C++ 2008 Redistributable Package (x86) from the following location:
//microsoft.com/downloads/details.aspx?familyid=9B2DA534-3E03-4391-8A4D-074B9F2BC1BF&displaylang=en
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 14
Description
When using the Virtual Media with recent Windows releases on the management station, the CD/DVD redirection may not
work properly and may cause continuous USB bus resets if you have logged in using non-administrator account.
Resolution
Set the
Attach Virtual Media
option to
Detach
to stop the USB bus resets and allow CD/DVD redirection to work properly
when you log in again with an Administrator's account.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 15
Description
When remote management is enabled, the
WWN/MAC
page may not immediately display the remotely enabled MACs and
instead may display N/A under the remotely assigned column. This may happen when you navigate to the to the
WWN/MAC
page for the first time.
Resolution
If this happens, navigate to a different page in the iDRAC6 Web interface and then return to the
WWN/MAC
page to see the
remotely assigned MACs. Ensure the host system has booted before navigating to the
WWN/MAC
page when remote
management is enabled.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 16
Description
When you access the iDRAC Web interface in IPv6 network with Mozilla Firefox 4.0 or later and accept the CSR certificate, it
displays an error message, "An error has occurred during a connection to <server certificate info>, Peer certificate issuer
has been marked as not trusted by the user. (Error code: sec_error_untrusted_issuer)."