Release Notes
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 6
Description
The
racresetcfg
command in RACADM restores all properties to their default values except
cfgDNSRacName
in the
cfgLanNetworking
group.
When using a configuration file with RACADM to configure iDRAC6, changing objects that affect the network connection
stops the rest of the configuration file from taking effect.
Resolution
N/A
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 7
Description
When using a configuration file with RACADM to configure iDRAC6, changing objects that affect the network connection
stops the rest of the configuration file from taking effect.
Resolution
Not applicable.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 8
Description
Using the iDRAC Web interface to shut down the XenServer operating system by selecting
Graceful Shutdown
does not shut
down the server.
Resolution
It is recommended that you use the shutdown menu option in the XenServer console or in the XenCenter management GUI.
Versions/Systems Affected
All iDRAC6 supported Dell PowerEdge systems.
Issue 9
Description
TFTP firmware update from local RACADM does not work after a racresetcfg or if IPv6 addresses are used.
Resolution
Use the firmware RACADM for TFTP firmware update.