Release Notes
These values are respectively named the following in the 3.21 release:
•
cfgServerPowerLastDayMinPowerTime
•
cfgServerPowerLastDayMaxPowerTime
•
cfgServerPowerLastWeekMinPowerTime
•
cfgServerPowerLastWeekMaxPowerTime
Issue 39
Description
The RACADM Command Line Reference Guide for iDRAC6 1.7, iDRAC 3.2, and CMC 3.2 defines that the drive is not available
to mount as RFS if a virtual drive is already used by Virtual Media, and vice versa. However, the remoteimage command
'racadm remoteimage -c -u [user] -p [password] -l [path]’ terminates the connected virtual media.
Issue 40
Description
The RACADM Command Line Reference Guide for iDRAC6 1.7, iDRAC6 3.2, and CMC 3.2 defines the legal values for the
cfgRacTuneIpRangeMask as a sequence of "1" from the left to the right, followed by some number of "0" (the network range).
RACADM output for setting invalid netmask addresses reports successful but will be not updated in iDRAC 3.30 firmware.
Issue 41
Description
Integrated Dell Remote Access Controller 6 (iDRAC6) Version 1.7 User Guide defines the GUI interface link as "Remote
Access" instead of "iDRAC Settings".
Issue 42
Description
Accessing iDRAC GUI in IPv6 network with Mozilla Firefox 4.0 or later [Mozilla Firefox 5.0], and accepting the CSR certificate
displays an error message, "An error has occurred during a connection to <server certificate info>, Peer certificate issuer has
been marked as not trusted by the user. (Error code:sec_error_untrusted_issuer)."
Resolution
Create a certificate request and issue it to a trusted domain. Register it to a domain DNS server. Use a trusted domain name,
instead of the IPv6 address.
Issue 43
Description
Accessing the iDRAC virtual console displays UNKNOWN publisher name message during certificate download.