Users Guide

94 Configuring iDRAC6 Enterprise Using the Web Interface
Configuring Platform Events
Platform event configuration provides a mechanism for configuring iDRAC6
to perform selected actions on certain event messages. The actions include no
action, reboot system, power cycle system, power off system, and generate an
alert (Platform Event Trap [PET] and/or e-mail).
The filterable platform events are listed in Table 5-7.
When a platform event occurs (for example, a Battery Probe Warning),
a system event is generated and recorded in the System Event Log (SEL).
If this event matches a platform event filter (PEF) that is enabled and you
have configured the filter to generate an alert (PET or e-mail), then a PET or
e-mail alert is sent to one or more configured destinations.
If the same platform event filter is also configured to perform an action
(such as rebooting the system), the action is performed.
Table 5-7. Filterable Platform Events
Index Platform Event
1 Battery Warning Assert Filter
2 Battery Critical Assert Filter
3 Voltage Critical Assert Filter
4 Temperature Warning Assert Filter
5 Temperature Critical Assert Filter
6 Processor Critical Assert Filter
7 Processor Absent Critical Assert Filter
8 Event Log Critical Assert Filter
9 Watchdog Critical Assert Filter
10 Removable Flash Media Warning Assert Filter
11 Removable Flash Media Absent Informational Assert Filter
12 Removable Flash Media Critical Assert Filter
13 Redundancy Lost Filter
14 Key Management Critical Assert Filter