Users Guide

Recovering and Troubleshooting the Managed System 371
Critical System Board Video Riser:
Module sensor for System Board,
device removed was asserted
Required module was removed
Critical Mezz B<slot number> Status:
Add-in Card sensor for Mezz
B<slot number>, install error
was asserted
Incorrect Mezzanine card
installed for IO fabric
Critical Mezz C<slot number> Status:
Add-in Card sensor for Mezz
C<slot number>, install error
was asserted
Incorrect Mezzanine card
installed for I/O fabric
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive removed
Storage drive was removed
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive fault was asserted
Storage drive failed
Critical System Board PFault Fail Safe:
Voltage sensor for System Board,
state asserted was asserted
This event is generated when
the system board voltages are
not at normal levels
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, timer expired was asserted
iDRAC6 watchdog timer
expired and no action is set
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, reboot was asserted
iDRAC6 watchdog detected
that the system has crashed
(timer expired because no
response was received from
Host) and the action is set to
reboot
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, power off was asserted
iDRAC6 watchdog detected
that the system has crashed
(timer expired because no
response was received from
Host) and the action is set to
power off
Table 19-6. Server Status Screen
(continued)
Severity Message Cause