When a platform event occurs (for example, a Battery Probe Warning),
a system event is generated and recorded in the System Event Log (SEL).
If this event matches a platform event filter (PEF) that is enabled and you
have configured the filter to generate an alert (PET or e-mail), then a PET or
e-mail alert is sent to one or more configured destinations.
If the same platform event filter is also configured to perform an action
(such as rebooting the system), the action is performed.
Configuring Platform Event Filters (PEF)
NOTE: Configure platform event filters before you configure the platform event
traps or e-mail alert settings.
1
Log in to iDRAC6 Web interface.
2
Click
System
, and then click the
Alert Management
tab.
The
Platform Events
screen appears.
3
Select the
Enable Paltform Event Filter Alerts
checkbox. You must select
this option for any platform alert to be sent to a valid destination.
4
Select one of the following action you want to enable for each event:
Reboot System - When an event occurs, the system restarts (a warm
boot).
Power Cycle System - When an event occurs, the system shuts down,
powers off, and restarts (a cold boot).
Power Off System - When an event occurs, the system shuts down and
powers off.
No Action - When an event occurs, no action is performed. This is the
default setting for an event.
5
Select the
Generate Alert
option beside each event for which you want an
alert to be generated.
NOTE: You can enable or disable alert generation for all events by selecting or
deselecting the check box next to the Generate Alert column heading.
6
Click
Apply
.