Users Guide

Table Of Contents
Configuring iDRAC6 Enterprise 55
NOTE: If you deselect the Preserve Configuration check box, iDRAC6 resets
to its default settings. In the default settings, the LAN is disabled, and you
cannot log in to iDRAC6 Web interface. You must reconfigure the LAN settings
using iDRAC6 Configuration Utility during BIOS POST or through CMC.
6
By default, the
Preserve Configuration
option is enabled (checked) to preserve
the current settings on iDRAC6 after an upgrade. If you do not want the
settings to be preserved, clear the
Preserve Configuration
check box.
7
Click
Begin Update
to start the upgrade process. Do not interrupt the
upgrade process.
8
In the
Upload (Step 3 of 3)
window, you will see the status of the update.
The progress of the firmware upgrade operation, measured in percentage,
appears in the
Progress
column.
9
Once the firmware update is complete, the
Upload (Step 3 of 3)
window
will refresh with the result and iDRAC6 will reset automatically. You must
close the current browser window and reconnect to iDRAC6 using a new
browser window.
Updating iDRAC6 Firmware Using RACADM
You can update iDRAC6 firmware using remote RACADM.
1
Download iDRAC6 firmware image from the Dell Support website at
support.dell.com
to the managed system.
For example:
C:\downloads\firmimg.imc
2
Run the following RACADM command:
For example:
racadm -r <iDRAC6 IP address> -u <username> -p
<password> fwupdate -g -u -a <path>
where
path
is the location on the TFTP server where
firmimg.imc
is stored.