362 Recovering and Troubleshooting the Managed System
Warning Link Tuning: Version Change
sensor, successful software or
F/W change was deasserted
Failed to update link tuning
setting for proper NIC operation
Warning Link Tuning: Version Change
sensor, successful hardware
change <device slot number>
was deasserted
Failed to update link tuning
setting for proper NIC operation
Critical LinkT/FlexAddr: Link Tuning
sensor, failed to program virtual
MAC address (Bus # Device #
Function #) was asserted
FlexAddress could not be
programmed for this device
Critical LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or flex
address (Mezz <location>)
was asserted
Option ROM does not support
FlexAddress or linking tuning
Critical LinkT/FlexAddr: Link Tuning
sensor, failed to get link tuning or
flex address data from
BMC/iDRAC6 was asserted
Failed to obtain linking tuning
or FlexAddress information
from BMC/iDRAC6
Critical LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or
FlexAddress (Mezz XX) was
asserted
This event is generated when
the PCI device Option ROM
for a NIC does not support
link tuning or the Flex
addressing feature
Critical LinkT/FlexAddr: Link Tuning
sensor, failed to program the
virtual MAC address
(<location>) was asserted
This event is generated when
the BIOS fails to program the
virtual MAC address on the
given NIC device
Critical I/O Fatal Err: Fatal IO Group
sensor, fatal IO error
(<location>)
This event is generated in
association with a CPU IERR
and indicates which device
caused the CPU IERR
Table 19-8. Server Status Screen
(continued)