Users Guide

Table Of Contents
Recovering and Troubleshooting the Managed System 361
Critical POST Err: POST sensor,
Dell remote access controller
configuration failed
Dell Remote Access Controller
configuration failure
Critical POST Err: POST sensor,
CPU configuration failed
CPU configuration failure
Critical POST Err: POST sensor,
Incorrect memory configuration
Incorrect memory
configuration
Critical POST Err: POST sensor,
POST failure
General failure after video
Critical Hdwar version err: Version
Change sensor, hardware
incompatibility was asserted
Incompatible hardware was
detected
Critical Hdwar version err: Version
Change sensor, hardware
incompatibility (BMC firmware)
was asserted
Hardware is incompatible with
the firmware
Critical Hdwar version err: Version
Change sensor, hardware
incompatibility (BMC firmware
and CPU mismatch) was asserted
CPU and firmware not
compatible
Critical Mem Overtemp: Memory sensor,
correctable ECC <DIMM
Location> was asserted
Memory module overheating
Critical Mem Fatal SB CRC: Memory
sensor, uncorrectable ECC
was asserted
South bridge memory failed
Critical Mem Fatal NB CRC: Memory
sensor, uncorrectable ECC
was asserted
North bridge memory failed
Critical WatchDog Timer: Watchdog
sensor, reboot was asserted
Watch dog timer caused
system to reboot
Critical WatchDog Timer: Watchdog
sensor, timer expired was asserted
Watch dog timer expired but
no action taken
Table 19-8. Server Status Screen
(continued)
Severity Message Cause