Critical System Board PFault Fail Safe:
Voltage sensor for System Board,
state asserted was asserted
This event is generated when
the system board voltages are
not at normal levels
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, timer expired was asserted
iDRAC6 watchdog timer
expired and no action is set
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, reboot was asserted
iDRAC6 watchdog detected
that the system has crashed
(timer expired because no
response was received from
Host) and the action is set to
reboot
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, power off was asserted
iDRAC6 watchdog detected
that the system has crashed
(timer expired because no
response was received from
Host) and the action is set to
power off
Critical System Board OS Watchdog:
Watchdog sensor for System
Board, power cycle was asserted
iDRAC6 watchdog detected
that the system has crashed
(timer expired because no
response was received from
Host) and the action is set to
power cycle
Critical System Board SEL: Event Log
sensor for System Board, log full
was asserted
The SEL device detects that
only one entry can be added to
the SEL before it is full
Warning ECC Corr Err: Memory sensor,
correctable ECC
( <DIMM Location> ) was
asserted
Correctable ECC errors
reached a critical rate
Critical ECC Uncorr Err: Memory sensor,
uncorrectable ECC
( <DIMM Location> ) was
asserted
An uncorrectable ECC error
was detected