Users Guide

Table Of Contents
356 Recovering and Troubleshooting the Managed System
Critical CPU<number> Status:
Processor sensor for
CPU<number, IERR was
asserted
CPU failure
Critical CPU<number> Status:
Processor sensor for
CPU<number>, thermal tripped
was asserted
CPU overheated
Critical CPU<number> Status:
Processor sensor for
CPU<number, configuration
error was asserted
Incorrect processor type or in
wrong location
Critical CPU<number> Status:
Processor sensor for
CPU<number>, presence was
deasserted
Required CPU is missing or
not present
Critical System Board Video Riser:
Module sensor for System Board,
device removed was asserted
Required module was removed
Critical Mezz B<slot number> Status:
Add-in Card sensor for Mezz
B<slot number>, install error
was asserted
Incorrect Mezzanine card
installed for IO fabric
Critical Mezz C<slot number> Status:
Add-in Card sensor for Mezz
C<slot number>, install error
was asserted
Incorrect Mezzanine card
installed for I/O fabric
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive removed
Storage drive was removed
Critical Backplane Drive <number>:
Drive Slot sensor for Backplane,
drive fault was asserted
Storage drive failed
Table 19-8. Server Status Screen
(continued)