Users Guide

Table Of Contents
Recovering and Troubleshooting the Managed System 355
Checking the Server Status Screen for Error Messages
When a flashing amber LED is lit, and a particular server has an error,
the main Server Status Screen on the LCD will highlight the affected server
in orange. Use the LCD navigation buttons to highlight the affected server,
then click the center button. Error and warning messages will be displayed on the
second line. The following table lists all of the error messages and their severity.
Table 19-8. Server Status Screen
Severity Message Cause
Warning System Board Ambient Temp:
Temperature sensor for System
Board, warning event
Server ambient temperature
crossed a warning threshold
Critical System Board Ambient Temp:
Temperature sensor for System
Board, failure event
Server ambient temperature
crossed a failure threshold
Critical System Board CMOS Battery:
Battery sensor for System Board,
failed was asserted
CMOS battery is not present or
has no voltage
Warn in g Sy st em Boa rd Syst em L ev el:
Current sensor for System Board,
warning event
Current crossed a warning
threshold
Critical System Board System Level:
Current sensor for System Board,
failure event
Current crossed a failure
threshold
Critical CPU<number> <voltage sensor
name>: Voltage sensor for
CPU<number>, state asserted
was asserted
Voltage out of range
Critical System Board <voltage sensor
name>: Voltage sensor for
System Board, state asserted was
asserted
Voltage out of range
Critical CPU<number> <voltage sensor
name>: Voltage sensor for
CPU<number>, state asserted
was asserted
Voltage out of range