120 Configuring iDRAC6 Enterprise Using the Web Interface
6
Click the
Apply iDRAC6 Enterprise Update
button below iDRAC6
component list.
7
Click
Browse
, browse to iDRAC6 firmware image you downloaded, and
click
Open
.
8
Click
Begin Firmware Update
.
After the firmware image file has been uploaded to CMC, iDRAC6 updates
itself with the image.
iDRAC6 Firmware Rollback
iDRAC6 has the provision to maintain two simultaneous firmware images.
You can choose to boot from (or rollback to) the firmware image of your choice.
1
Open iDRAC6 Web interface and log in to the remote system.
Click
System
Remote Access
iDRAC6
, and then click the
Update
tab.
2
Click
Rollback
. The current and the rollback firmware versions are
displayed on the
Rollback (Step 2 of 3)
page.
3
Click
Next
to start the firmware rollback process.
On the
Rollback (Step 3 of 3)
page, you see the status of the
rollback operation. On successful completion, it shows that the process
completed successfully.
If the firmware rollback is successful, iDRAC6 will reset automatically. To
continue working with iDRAC6 through the Web interface, close the
current browser and reconnect to iDRAC6 using a new browser window.
An appropriate error message is displayed if an error occurs.
NOTE: The Preserve Configuration feature does not work if you want to
rollback iDRAC6 firmware from version 2.2 to version 2.1.