Users Guide

Table Of Contents
118 Configuring iDRAC6 Enterprise Using the Web Interface
Updating iDRAC6 Firmware
NOTE: If iDRAC6 firmware becomes corrupted, as could occur if iDRAC6 firmware
update is interrupted before it completes, you can recover iDRAC6 using CMC. See
your
CMC Firmware User Guide
for instructions.
NOTE: The firmware update, by default, retains the current iDRAC6 settings.
During the update process, you have the option to reset iDRAC6 configuration to the
factory defaults. If you set the configuration to the factory defaults, external
network access will be disabled when the update completes. You must enable and
configure the network using iDRAC6 Configuration Utility or CMC Web interface.
1
Start iDRAC6 Web interface.
2
Click
System
Remote Access
iDRAC6
, and then click the
Update
tab.
The
Firmware Update
screen appears.
NOTE: To update the firmware, iDRAC6 must be placed in an update mode.
Once in this mode, iDRAC6 will automatically reset, even if you cancel the
update process.
3
In the
Upload
section, click
Browse
and select the firmware image.
For example:
C:\Updates\V2.2\<
image_name
>
.
The default firmware image name is
firmimg.imc
.
4
Click
Upload
. The file will be uploaded to iDRAC6. This may take several
minutes to complete.
5
In the
Upload (Step 2 of 3)
screen, you will see the results of the
validation performed on the image file you uploaded.
If the image file is uploaded successfully and passed all verification
checks, a message will appear indicating that the firmware image has
been verified.
If the image did not upload successfully, or it did not pass the
verification checks, reset iDRAC6, close the current session, and then
try updating again.