Users Guide

352 RACADM Subcommand Overview
racresetcfg
Table A-15 describes the racresetcfg subcommand.
Synopsis
racadm racresetcfg
Supported Interfaces
Local RACADM
Remote RACADM
telnet/ssh RACADM
Description
The racresetcfg command removes all user-configured database property
entries. The database has default properties for all entries that are used to
restore iDRAC6 back to the default settings.
NOTE: This command deletes your current iDRAC6 configuration, disables DHCP,
and resets iDRAC6 configuration to the default settings. After reset, the default
name and password are root and calvin, respectively, and the IP address is
192.168.0.120 plus the number of the slot the server inhabits in the chassis.
serveraction
Table A-16 describes the serveraction subcommand.
Table A-15. racresetcfg
Subcommand Definition
racresetcfg Resets the entire iDRAC6 configuration to factory default
values.
NOTE: The racresetcfg subcommand does not reset the
cfgDNSRacName object.
Table A-16. serveraction
Subcommand Definition
serveraction Executes a managed server reset or power-on/off/cycle.