Users Guide

58 Configuring iDRAC6 Enterprise
Using the iDRAC6 Configuration Utility to Enable Discovery and
Monitoring
To set up iDRAC6 for IPMI discovery and alert trap sending at the iDRAC6
Configuration Utility level, restart your managed server (blade) and observe
its power-up using the iKVM and either a remote monitor and console
keyboard or a Serial over LAN (SOL) connection. When Press
<Ctrl-E> for Remote Access Setup displays, press <Ctrl><E>.
When the iDRAC Configuration Utility screen appears, use the arrow keys
to scroll down.
1
Enable
IPMI over LAN
.
2
Enter your site's
RMCP+ Encryption Key
, if used.
NOTE: See your senior Network Administrator or CIO to discuss implementing
this option because it adds valuable security protection and must be implemented
site-wide in order to function properly.
3
At
LAN Parameters
, press <Enter> to enter the sub-screen. Use Up and
Down arrows to navigate.
4
Toggle
LAN Alert Enabled
to
On
using the spacebar.
5
Enter the IP address of your Management Station into
Alert Destination 1
.
6
Enter a name string into
iDRAC6 Name
with a consistent naming convention
across your data center. The default is
iDRAC6-{
Service Tag
}
.
Exit the iDRAC6 Configuration Utility by pressing <Esc>, <Esc>, and then
pressing <Enter> to save your changes. Your server will now boot into normal
operation, and it will be discovered during IT Assistant's next scheduled
Discovery pass.
Using the iDRAC6 Web Interface to Enable Discovery and Monitoring
IPMI Discovery can also be enabled through the remote Web interface:
1
Open a supported Web browser window.
2
Log in to the iDRAC6 Web-based interface using a login and password
with Administrator rights.
3
In the system tree, select
System
Remote Access
iDRAC
.
4
Click the
Network/Security
tab.
The
Network Configuration
screen appears.