Users Guide
290 Recovering and Troubleshooting the Managed Server
Viewing the iDRAC6 Log
The iDRAC6 Log is a persistent log maintained in iDRAC6 firmware.
The log contains a list of user actions (such as log in, log out, and security
policy changes) and alerts issued by iDRAC6. The oldest entries are
overwritten when the log becomes full.
Where the System Event Log (SEL) contains records of events that occur in
the managed server, the iDRAC Log contains records of events that occur in
iDRAC6.
To access the iDRAC Log, perform the following steps:
• Click
System
→
Remote Access
→
iDRAC
and
then click
iDRAC Log
.
The iDRAC Log provides the information in Table 17-9.
Critical LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or flex
address (Mezz XX) was asserted
This event is generated when
the PCI device Option ROM
for a NIC does not support
link tuning or the Flex
addressing feature
Critical LinkT/FlexAddr: Link Tuning
sensor, failed to program the
virtual MAC address
(<location>) was asserted
This event is generated when
the BIOS fails to program the
virtual MAC address on the
given NIC device
Critical I/O Fatal Err: Fatal IO Group
sensor, fatal IO error
(<location>)
This event is generated in
association with a CPU IERR
and indicates which device
caused the CPU IERR
Warning PCIE NonFatal Er: Non Fatal I/O
Group sensor, PCIe error
(<location>)
This event is generated in
association with a CPU IERR
Table 17-8. Server Status Screen (continued)
Severity Message Cause