Users Guide

Recovering and Troubleshooting the Managed Server 287
Critical PCIE Fatal Err: Critical Event
sensor, bus fatal error was asserted
Fatal error is detected on the
PCIE bus
Critical Chipset Err: Critical Event
sensor, PCI PERR was asserted
Chip error is detected
Warning Mem ECC Warning: Memory
sensor, transition to non-critical
from OK (<DIMM Location> )
was asserted
Correctable ECC errors have
increased from a normal rate
Critical Mem ECC Warning: Memory
sensor, transition to critical from
less severe ( <DIMM Location> )
was asserted
Correctable ECC errors have
reached a critical rate
Critical POST Err: POST sensor,
No memory installed
No memory detected on board
Critical POST Err: POST sensor, Memory
configuration error
Memory detected but is not
configurable
Critical POST Err: POST sensor,
Unusable memory error
Memory configured but
not usable
Critical POST Err: POST sensor,
Shadow BIOS failed
System BIOS shadow failure
Critical POST Err: POST sensor,
CMOS failed
CMOS failure
Critical POST Err: POST sensor,
DMA controller failed
DMA controller failure
Critical POST Err: POST sensor,
Interrupt controller failed
Interrupt controller failure
Critical POST Err: POST sensor,
Timer refresh failed
Timer refresh failure
Critical POST Err: POST sensor,
Programmable interval
timer error
Programmable interval
timer error
Critical POST Err: POST sensor,
Parity error
Parity error
Table 17-8. Server Status Screen (continued)
Severity Message Cause