Users Guide
Recovering and Troubleshooting the Managed Server 283
Critical System Board System Level:
Current sensor for System Board,
failure event
Current crossed a failure
threshold
Critical CPU<number> <voltage sensor
name>: Voltage sensor for
CPU<number>, state asserted
was asserted
Voltage out of range
Critical System Board <voltage sensor
name>: Voltage sensor for
System Board, state asserted was
asserted
Voltage out of range
Critical CPU<number> <voltage sensor
name>: Voltage sensor for
CPU<number>, state asserted
was asserted
Voltage out of range
Critical CPU<number> Status:
Processor sensor for
CPU<number, IERR was
asserted
CPU failure
Critical CPU<number> Status:
Processor sensor for
CPU<number>, thermal tripped
was asserted
CPU overheated
Critical CPU<number> Status:
Processor sensor for
CPU<number, configuration
error was asserted
Incorrect processor type or in
wrong location
Critical CPU<number> Status:
Processor sensor for
CPU<number>, presence was
deasserted
Required CPU is missing or
not present
Critical System Board Video Riser:
Module sensor for System Board,
device removed was asserted
Required module was removed
Table 17-8. Server Status Screen (continued)
Severity Message Cause