Users Guide
Critical(严重)
System Board CMOS Battery: Battery sensor for System Board, failed
wasasserted
(系统板 CMOS 电池:系统板的电池传感器,故障已声明)
CMOS 电池不存在或没有电压
"Warning"(警
告)
System Board System Level: Current sensor for System Board, warning event
(系统板系统水平:系统板的电流传感器,警告事件)
电流越过警告阈值
Critical(严重)
System Board System Level: Current sensor for System Board, failure event
(系统板系统水平:系统板的电流传感器,故障事件)
电流越过故障阈值
Critical(严重)
CPU<number> <voltage sensor name>: Voltage sensor for CPU<number>,
state asserted was asserted
(CPU<编号> <电压传感器名称>:CPU<编号> 的电压传感器,声明的状态已声明)
电压超出范围
Critical(严重)
System Board <voltage sensor name>: Voltage sensor for System Board,
state asserted was asserted
(系统板<电压传感器名称>:系统板的电压传感器,声明的状态已声明)
电压超出范围
Critical(严重)
CPU<number> <voltage sensor name>: Voltage sensor for CPU<number>,
state asserted was asserted
(CPU<编号> <电压传感器名称>:CPU<编号> 的电压传感器,声明的状态已声明)
电压超出范围
Critical(严重)
CPU<number> Status: Processor sensor for CPU<number, IERR was asserted
(CPU<编号> 状态:CPU<编号> 的处理器传感器,IERR 已声明)
CPU 故障
Critical(严重)
CPU<number> Status: Processor sensor for CPU<number>, thermal tripped
was asserted
(CPU<编号> 状态:CPU<编号> 的处理器传感器,热断路已声明)
CPU 过热
Critical(严重)
CPU<number> Status: Processor sensor for CPU<number, configuration error
was asserted
(CPU<编号> 状态:CPU<编号> 的处理器传感器配置错误已声明)
处理器类型不正确或位置错误
Critical(严重)
CPU<number> Status: Processor sensor for CPU<number>, presence was
deasserted
(CPU<编号> 状态:CPU<编号> 的处理器传感器,存在已取消声明)
所需 CPU 缺少或不存在
Critical(严重)
System Board Video Riser: Module sensor for System Board, device removed
was asserted
(系统板视频升降器:系统板的模块传感器,拆卸的设备已声明)
已拆卸所需模块
Critical(严重)
Mezz B<slot number> Status: Add-in Card sensor for Mezz B<slot number>,
install error was asserted
(Mezz B<插槽编号> 状态:Mezz B<插槽编号> 的添加式插卡传感器,安装错误已声明)
为 IO 结构安装的夹层卡不正确
Critical(严重)
Mezz C<slot number> Status: Add-in Card sensor for Mezz C<slot number>,
install error was asserted
(Mezz C<插槽编号> 状态:Mezz C<插槽编号> 的添加式插卡传感器,安装错误已声明)
为 I/O 结构安装的夹层卡不正确
Critical(严重)
Backplane Drive <number>: Drive Slot sensor for Backplane, drive removed
(背板驱动器 <编号>:背板的驱动器插槽传感器,驱动器已拆卸)
存储驱动器已拆卸
Critical(严重)
Backplane Drive <number>: Drive Slot sensor for Backplane, drive fault was
asserted
(背板驱动器 <编号>:背板的驱动器插槽传感器,驱动器故障已声明)
存储驱动器故障
Critical(严重)
System Board PFault Fail Safe: Voltage sensor for System Board, state
asserted was asserted
(系统板 PFault 故障防护:系统板的电压传感器,声明的状态已声明)
在系统板电压未处于正常水平时生成此事件
Critical(严重)
System Board OS Watchdog: Watchdog sensor for System Board, timer
expired was asserted
(系统板操作系统监护程序:系统板的监护程序传感器,过期的计时器已声明)
iDRAC6 监护程序计时器已过期并且没有设置操作
Critical(严重)
System Board OS Watchdog: Watchdog sensor for System Board, reboot was
asserted
(系统板操作系统监护程序:系统板的监护程序传感器,重新引导已声明)
iDRAC6 监护程序检测到系统已崩溃(由于没有从主机收到响应,因此
计时器过期),并且操作设置为重新引导
Critical(严重)
System Board OS Watchdog: Watchdog sensor for System Board, power off
was asserted
(系统板操作系统监护程序:系统板的监护程序传感器,关机已声明)
iDRAC6 监护程序检测到系统已崩溃(由于没有从主机收到响应,因此
计时器过期),并且操作设置为关机
Critical(严重)
System Board OS Watchdog: Watchdog sensor for System Board, power cycle
was asserted
(系统板操作系统监护程序:系统板的监护程序传感器,关机并重新打开电源已声明)
iDRAC6 监护程序检测到系统已崩溃(由于没有从主机收到响应,因此
计时器过期),并且操作设置为关机并重新打开电源
Critical(严重)
System Board SEL: Event Log sensor for System Board, log full was asserted
(系统板 SEL:系统板的事件日志传感器,日志已满已声明)
SEL 设备检测到再向 SEL 添加一个条目后它就已满
"Warning"(警
告)
ECC Corr Err: Memory sensor, correctable ECC
( <DIMM Location> ) was asserted
(ECC 校正错误:内存传感器,可校正 ECC
(<DIMM 位置>) 已声明)
可校正的 ECC 错误达到严重水平
Critical(严重)
ECC Uncorr Err: Memory sensor, uncorrectable ECC
( <DIMM Location> ) was asserted
(ECC 不可校正错误:内存传感器,不可校正的 ECC
(<DIMM 位置>) 已声明)
已检测到一个不可校正的 ECC 错误
Critical(严重)
I/O Channel Chk: Critical Event sensor, I/O channel check NMI was asserted
(I/O 信道检查:严重事件传感器,I/O 信道检查 NMI 已声明)
I/O 信道中生成一个严重中断
Critical(严重)
PCI Parity Err: Critical Event sensor, PCI PERR was asserted
(PCI 奇偶校验错误:严重事件传感器,PCI PERR 已声明)
在 PCI 总线上检测到奇偶校验错误
Critical(严重)
PCI System Err: Critical Event sensor, PCI SERR
( <Slot number or PCI Device ID>) was asserted
(PCI 系统错误:关键事件传感器,PCI SERR
(<插槽编号或 PCI 设备 ID>)已声明)
设备检测到 PCI 错误
Critical(严重)
SBE Log Disabled: Event Log sensor, correctable memory error logging
disabled was asserted
(SBE 日志禁用:事件日志传感器,禁用的可校正内存错误记录已声明)
如果记录的 SBE 太多,会禁用单位错误记录