Release Notes
Table Of Contents
Table 5. Known issues on Linux operating system (continued)
Issue ID Functional area Description Workaround
path, when the following features are
either enabled or disabled:
● iDRAC Access via Host operating
system
● Host SNMP Alerts
124514 A message is displayed
when invoking iDRAC
UI Launcher for the
first time
When invoking iDRAC GUI Launcher
for the first time either using
iDRACLauncher.sh or the program menu
shortcut, the following message is
displayed in operating system log files:
"localhost dbus-daemon[2369]:
[system] Activating via
systemd: service
name='net.reactivated.Fprint'u
nit='fprintd.service'
requested by ':1.18176' (uid=0
pid=126684 comm="sudo -l /opt/
dell/srvadmin/iSM/bin/
InvokeiDRACLau"label="unconfin
ed_u:unconfined_r:unconfined_t
:s0-s0:c0.c1023")"
There is no functional impact. No
action is required.
199162 SupportAssist
registration
SupportAssist registration is not successful
on Linux operating system, when the
internet connectivity to the server is
configured through the proxy.
Not available
Known issues on VMware ESXi operating system
Table 6. Known issues on VMware ESXi operating system
Issue ID Functional area Description Workaround
172915 iSM communication
with iDRAC is
interrupted.
In VMware ESXi 7.x, iDRAC Service
Module (iSM) communication with iDRAC
is dropped.
No action is required as
the communication is restored
automatically within 1–2 minutes.
176426 Communication is
not restarting after
performing Restart
Management Agents.
iDRAC Service Module is not restarting
the communication with iDRAC after
performing Restart Management Agents
on VMWare ESXi 7.x.
You must try performing
Restart Management Agents again
immediately after the first attempt.
Not available. IPMI driver becomes
unresponsive on
VMware ESXi.
After performing an iDRAC hard reset
operation on certain VMware ESXi, the
ipmi_si_drv IPMI driver on ESXi 6.x and
ipmi IPMI drive on ESXi 6.x/7.x do not
respond because of an existing issue in
the IPMI driver. If the IPMI driver becomes
unresponsive, reload the ipmi_si_drv IPMI
driver on ESXi 6.x and ipmi IPMI drive on
ESXi 6.x/7.x.
The issue is observed in
iDRAC Service Module 2.3 and
later supported ESXi versions.
To reload the IPMI driver,
run the following commands:
esxcli system wbem set
-e 0 esxcfg-module -u
ipmi_si_drv/ipmi => unload
ipmi_si_drv/ipmi esxcfg-
module ipmi_si_drv/ipmi
=> load ipmi_si_drv/ipmi
esxcfg-module ipmi_si_drv/
ipmi => load ipmi_si_drv/
ipmi esxcli system wbem
set -e 1
6