Users Guide

Table Of Contents
software-defined alerts that are covered by operating system log files are merged, and the alerts are registered in the iDRAC
Lifecycle log files.
This feature is installed with the iSM package and will be enabled by default. You can change the preferences in the iDRAC
settings. As part of the monitoring, iSM will audit the log files for potential failures and warnings. iSM will embed the SS
correlation events on the host to an equivalent Lifecycle Controller event. The SSLCMAP should only reach the Lifecycle log
files and SupportAssist alert. You cannot configure the SSLCMAP to any other alert destination in iDRAC .
The following are the prerequisites for S2D log collection:
The SS event correlation feature must be enabled in the service module page in the iDRAC UI.
The PII filter must be disabled in the service module page in the iDRAC UI.
Table 14. Windows Event Message mapped under LC logs monitored under S2D event correlation
Windows event sourceSourceID Windows event message Mapped on iDRAC LC log
StorageSpacesdrivers100 Physical drive %1 failed to read the
configuration or returned corrupt data
for storage pool %2. As a result the
in-memory configuration might not be
the most recent copy of configuration.
Return code: %3
MessageID : SDS0001
StorageSpacesdrivers102 Most of the physical drives of storage
pool %1 failed a configuration update,
which caused the pool to go into a failed
state. Return code: %2
MessageID : SDS0002
StorageSpacesdrivers103 The capacity consumption of the storage
pool %1 has exceeded the threshold limit
set on the pool. Return code: %2
MessageID : SDS0003
StorageSpacesdrivers200 Windows was unable to read the drive
header for physical drive %1. If you
know that the drive is still usable,
then resetting the drive health by using
command line or UI may clear this failure
condition and enable you to reassign the
drive to its storage pool. Return code:
%2
MessageID : SDS0004
StorageSpacesdrivers203 An I/O failure has occurred on physical
drive %1. Return code: %2
MessageID : SDS0005
StorageSpacesdrivers300 Physical drive %1 failed to read the
configuration or returned corrupt data
for storage space %2. As a result the
in-memory configuration may not be
the most recent copy of configuration.
Return code: %3
MessageID : SDS0006
StorageSpacesdrivers301 All pool drives failed to read the
configuration or returned corrupt data
for storage space %1. As a result the
storage space will not attach. Return
code: %2
MessageID : SDS0007
StorageSpacesdrivers302 Most of the pool drives hosting space
metadata for storage space %1 failed a
space metadata update, which caused
the storage pool to go to failed state.
Return code: %2
MessageID : SDS0008
StorageSpacesdrivers303 Drives hosting data for storage space
have failed or are missing. As a result,
no copy of data is available. Return code:
%2
MessageID : SDS0009
iSM monitoring features 37