Release Notes
Table Of Contents
- Dell EMC iDRAC Service Module 3.6 Release Notes
- Release summary
- Compatibility
- New in this release
- Known issues
- Common issues
- A warning message indicating the iSM communication restart is observed in both iDRAC Lifecycle log files and operating system log files
- Job Queue page displays the job as Firmware Update instead of OSCollector
- Increased workload on the host interrupts the communication between iSM and iDRAC
- ISM0003 event message after replacing the system board
- Registering SupportAssist Enterprise
- Enabling operating system information
- Known issues on Microsoft Windows operating systems
- Invoke-iDRACHardReset and Invoke-FullPowerCycle are not functional
- Alert message is displayed when OMSA is installed and TSR is requested
- An internal error occurred when running the DCIM_View class
- A popup is displayed when uninstalling iSM
- Running WMI MOF query on DCIM results with no data
- iSM communication with iDRAC switches from IPv6 to IPv4
- During the repair or modify operation on Microsoft Windows 2016 operating system installation, communication between the iSM and iDRAC is not established
- Known issues on Linux operating systems
- iSM communication with iDRAC is dropped, when Enable-iDRACAccessHostRoute feature is enabled and firewall service is disabled
- ipmi_si IPMI_driver does not respond after iDRAC hard reset
- InBand iDRAC Access feature is unavailable in IPv6 protocol
- AVC denial with iptables
- A message is displayed when invoking iDRAC GUI Launcher for the first time
- Known issues on VMware ESXi operating systems
- Common issues
- Limitations
- User notes
- Resources and support
- Contacting Dell EMC
User notes
Topics:
• User notes for supported Microsoft Windows operating systems
•
User notes for supported Red Hat Enterprise Linux and SUSE Linux Enterprise Server
User notes for supported Microsoft Windows
operating systems
To enable WSMan silently, use the following CLI command:
Msiexec.exe/i iDRACSvcMod.msi ADDLOCAL="WSMAN_Enablement" CP_SELF_SIGN_CERT="2"
CP_WSMAN_PORT="1234" CP_CERTIFICATE="1" CP_NEGOTIATE="1"/qn
User notes for supported Red Hat Enterprise Linux
and SUSE Linux Enterprise Server
● To perform an Express Install on Red Hat Linux Server and SUSE Linux Enterprise Server operating systems, run the
following command from the SYSMGMT/iSM/linux directory:
dcism-setup.sh -x
For more information on the installation instructions, refer to the iDRAC Service Module User's Guide.
● By default, you do not have permission to run the script directly on the disk partition. Run the following command to run the
script directly and initiate iDRAC Service Module installation:
sh ISM_Lx.sh or .ISM_Lx.sh
6
18 User notes