- New in this release
- Known issues
- Common issues
- A warning message indicating the iSM communication restart is observed in both iDRAC Lifecycle log files and operating system log files
- Job Queue page displays the job as Firmware Update instead of OSCollector
- Increased workload on the host interrupts the communication between iSM and iDRAC
- ISM0003 event message after replacing the system board
- Registering SupportAssist Enterprise
- Enabling operating system information
- Known issues on Microsoft Windows operating systems
- Invoke-iDRACHardReset and Invoke-FullPowerCycle are not functional
- Alert message is displayed when OMSA is installed and TSR is requested
- An internal error occurred when running the DCIM_View class
- A popup is displayed when uninstalling iSM
- Running WMI MOF query on DCIM results with no data
- iSM communication with iDRAC switches from IPv6 to IPv4
- During the repair or modify operation on Microsoft Windows 2016 operating system installation, communication between the iSM and iDRAC is not established
- Known issues on Linux operating systems
- iSM communication with iDRAC is dropped, when Enable-iDRACAccessHostRoute feature is enabled and firewall service is disabled
- ipmi_si IPMI_driver does not respond after iDRAC hard reset
- InBand iDRAC Access feature is unavailable in IPv6 protocol
- AVC denial with iptables
- A message is displayed when invoking iDRAC GUI Launcher for the first time
- Known issues on VMware ESXi operating systems
- Common issues
- Limitations
- User notes
- Resources and support
- Contacting Dell EMC
● On Windows operating systems, a feature that is enabled using the installer and disabled using any interface other than the
installer can only be enabled using the same interface or the installer in GUI mode.
● IPv6 support on Linux operating systems are not available for the following features:
○ iSM Auto Update
○ ismtech
○ Inband iDRAC Access
○ SNMP Get via Host operating system
Limitations on VMware ESXi operating systems
● Upgrading an earlier version of ESXi to ESXi 7.x is failing with iSM VIB installed. In VMware vSphere 7.0, 32-bit userworld
support is deprecated. For more information, see the Deprecation of 32-bit Userworld Support section in VMware vSphere
7.0 Release Notes and Known issues section in VMware vSphere 7.x on Dell EMC PowerEdge Servers Release Notes.
Workaround: Before upgrading an earlier version of ESXi to ESXi 7.0, uninstall the 32-bit iSM VIB corresponding to iSM
v3.5.0 or earlier on the hypervisor.
Tracking number: 148591
● When the small footprint CIM broker (SFCB) configuration is set to read-only mode in the VMware ESXi operating system,
iSM-Windows remote management (WinRM) commands such as iDRACHardreset, EnableInBandSNMPTraps do not function.
As a workaround, use the Invoke-iDRACHardReset command line utility to perform the iDRAC Hardreset operation.
● The iDRAC Access via Host operating system feature is not supported on VMware ESXi operating systems.
● When Local Racadm set is disabled through iDRAC interfaces:
○ iSM fails to configure the operating system to iDRAC passthru in the USB NIC mode.
○ iSM functionality is restored when Local Racadm set is enabled.
● EventID for Lifecycle Controller logs replicated to operating system log will be 0 for some of the past events.
● TrapID for In-band SNMP Traps will be 0 for some of the past traps.
● When iDRAC Hardreset is disabled in iDRAC and you perform an iDRAC Hardreset operation from the hypervisor operating
systems like VMware ESXi, the result indicates success although iDRAC is not reset.