Users Guide
I used the remote iDRAC hard reset feature to reset the
iDRAC. However, the IPMI is unresponsive and I am not able
to troubleshoot.
If you try to use the remote iDRAC hard reset feature on VMware ESXi operating system the IPMI drivers becomes
unresponsive, because of this the iDRAC Service Module communication is stopped. You may have to reboot the server and load
the IPMI driver again to resolve the issue.
Where do I find the Replicated LifeCycle log on my
Operating System?
To view the replicated LifeCycle logs:
Table 15. Frequently asked question
Operating System Location
Microsoft Windows
Event viewer > Windows Logs >
<Existing group or Custom
folder>
. All the iDRAC Service Module LifeCycle logs are
replicated under the source name iDRAC Service Module.
Red Hat Enterprise Linux, and SUSE Linux. /var/log/messages
VMware ESXi /var/log/syslog.log
Ubuntu /var/log/syslog
What is the default SNMP protocol configured in iDRAC
Service Module to send alerts in Linux operating systems?
By default, the SNMP multiplexing protocol (SMUX) is configured in iDRAC Service Module to send alerts.
SMUX is not supported on my system. Which protocol
should I configure to send alerts?
If SMUX is not supported on your system, Agent-x is used as a default protocol.
How do I configure iDRAC Service Module to use the
Agent-x protocol to send alerts by default?
You can configure Agent-x as the default protocol using ./Enable-iDRACSNMPTrap.sh 1/agentx –force command. If
–force is not specified, ensure that the net-SNMP is configured and restart the snmpd service.
What are the Linux-dependent packages or executables I
should install while completing the Linux installation?
To see the list of Linux-dependent packages, see Linux dependencies.
46
Frequently asked questions