Users Guide

Anonymous Collection of Report
Starting from iDRAC Service Module version 3.1, you can perform SupportAssist Collection/Upload without completing the
registration process. Until iSM 3.0.2, the registration was a prerequisite to perform SupportAssist Collection.
The supported iDRAC firmware for the anonymous collection is iDRAC 3.15.15.15 in the yx4x and yx5x servers and 2.60.60.60 in
the yx3x servers.
NOTE: You can perform Anonymous SupportAssist Collection upload using blank username or password in proxy
environment on the yx3x servers.
Correlation of software events to hardware failures for Microsoft SDS
Starting iSM 3.5, the event logs for hardware storage pool alerts or events will be monitored by iSM with Server Storage
correlation feature. Currently the server storage subsystem is monitored when Dell EMC storage controllers are used in RAID
mode. But in Storage Spaces(SS) or Storage Space Direct(S2D), the server storage subsystem is monitored in a pass-thru
mode or the SATA chipset is used to create the storage pool. With this feature, the hardware defined alerts covered by
Lifecycle log and software defined alerts covered by OS logs are merged and the alerts are registered in the iDRAC Lifecycle
logs.
This feature is installed with the iDRAC Service Module package and will be enabled by default. User can change the
preferences in the iDRAC settings. As part of the monitoring, iSM will audit the logs for potential failures and warnings. iSM will
embed the SS correlation events on the Host to an equivalent LC event. The SSLCMAP should only reach the Lifecycle logs and
SupportAssist alert. User cannot configure the SSLCMAP to any other alert destination in iDRAC .
The following are the pre-requisites for S2D log collection:
SS event correlation feature needs to be enabled in the service module page in iDRAC UI.
PII filter needs to be disabled in the service module page in iDRAC UI
Table 12. Windows Event Message mapped under LC logs monitored under S2D event correlation
Windows Event Source - SourceID Windows Event Message Mapped on iDRAC LC Log
StorageSpaces - Drivers - 100 Physical drive %1 failed to read the
configuration or returned corrupt data
for storage pool %2. As a result the in-
memory configuration might not be the
most recent copy of configuration.
Return Code: %3
MessageID : SDS0001
StorageSpaces - Drivers - 102 Majority of the physical drives of storage
pool %1 failed a configuration update,
which caused the pool to go into a failed
state. Return Code: %2
MessageID : SDS0002
StorageSpaces - Drivers - 103 The capacity consumption of the storage
pool %1 has exceeded the threshold limit
set on the pool. Return Code: %2
MessageID : SDS0003
StorageSpaces - Drivers - 200 Windows was unable to read the drive
header for physical drive %1. If you know
the drive is still usable, then resetting
the drive health by using command line
or GUI may clear this failure condition
and enable you to reassign the drive to
its storage pool. Return Code: %2
MessageID : SDS0004
StorageSpaces - Drivers - 203 An IO failure has occurred on Physical
drive %1 Return Code: %2
MessageID : SDS0005
StorageSpaces - Drivers - 300 Physical drive %1 failed to read the
configuration or returned corrupt data
for storage space %2. As a result the in-
memory configuration may not be the
most recent copy of configuration.
Return Code: %3
MessageID : SDS0006
iDRAC Service Module monitoring features 35