Release Notes
Limitations on VMware ESXi operating systems
● When the small footprint CIM broker (SFCB) configuration is set to read only mode in VMware ESXi operating system, iSM-
Windows remote management (WinRM) commands such as iDRACHardreset, and EnableInBandSNMPTraps does not
function.
Workaround: User can use Invoke-iDRACHardReset utility to perform the iDRAC hard reset operation.
● The iDRAC Access via Host OS feature is not supported on VMware ESXi Operating Systems.
● When Local Racadm set is disabled through iDRAC interfaces:
○ iDRAC Service Module will fail to configure the OS to iDRAC Pass-through in the USB NIC mode.
○ iDRAC Service Module functionality is restored when Local racadm set is enabled.
● EventID for Lifecycle Controller Logs replicated to OS log will be 0 for some of the past events.
● TrapID for In-band SNMP Traps will be 0 for some of the past traps.
● When iDRAC Hard Reset is disabled in iDRAC and user performs iDRACHardReset from the Hypervisor operating systems
like VMware ESXi, the result indicates success although iDRAC is not reset.
Limitations 15