Release Notes

Known issues
Common Issues
The issues that are mentioned in this section are common for all supported operating systems.
Table 3. Common issues
Issue ID Functional area Description Workaround
180859 iSM communication
restart is observed in
both iDRAC Lifecycle
Log files and operating
system log files.
When both iDRAC Service Module (iSM)
and OpenManage Server Administrator
(OMSA) services are running on the host
operating system, iSM communication with
iDRAC might stop and start every 5
hours 30 minutes automatically. A warning
message indicating the iSM communication
restart is observed in both iDRAC Lifecycle
log files and operating system log files.
Log Message: ISM0007 The iDRAC
Service Module communication
with iDRAC has ended.
No action is required as
iSM communication is restored
automatically within 12 minutes.
159410 Increased workload on
the host interrupts
communication
between iSM and
iDRAC.
When the workload on the host increases
due to intensive task requests by the
processor, communication between iSM
and iDRAC is temporarily interrupted
with the following warning message
in the Lifecycle log file: The iDRAC
Service Module communication
with iDRAC has ended.
The connection automatically
resumes and no action is required.
161262 ISM0003 event
message after replacing
the system board.
If a USB NIC is enabled after the
system board is replaced without restoring
the configuration or after the iDRAC
is reset to factory settings, you can
observe the following ISM0003 event
message on operating system log
files before starting the communication:
The iDRAC Service Module is
unable to discover iDRAC from
the operating system of the
server.
No action is required.
193255 Enabling operating
system information .
On enabling operating system information
when iSM is installed, IPv6 default
gateway address and DNS server fields are
not rendered in the iDRAC interfaces.
Not available.
Known issues on Microsoft Windows operating system
Table 4. Known issues on Microsoft Windows operating system
Issue ID Functional area Description Workaround
157981 An internal error
occurred when running
the DCIM_View class.
When DCIM_View class is enumerated
with any WSMAN client through the iSM's
WMI Info feature on PowerEdge yx5x
servers and iDRAC firmware 4.00.00.00
or later, the response is partial and fails
with the following error code 5: The
Enumerate the explicit classes
such as DCIM_CPUView,
DCIM_FANView, and so on.
4