Release Notes
Table Of Contents
Installation
On the Red Hat Enterprise Linux and SUSE Linux Enterprise Server operating systems, to perform an Express Install execute
dcism-setup.sh -x from the SYSMGMT/iSM/linux directory.
NOTE: On Microsoft Windows Operating Systems, to enable WSMAN silently, use the following CLI command:
Msiexec.exe /i iDRACSvcMod.msi ADDLOCAL="WSMAN_Enablement" CP_SELF_SIGN_CERT="2"
CP_WSMAN_PORT="1234" CP_CERTIFICATE="1" CP_NEGOTIATE="1" /qn
NOTE: On Red Hat Enterprise Linux, SUSE Linux Enterprise Server, and VMware ESX Operating Systems, you will not have
the permission to run the script directly on the disk partition. Please use the format “sh ISM_LX.sh” to run the script and
initiate iDRAC Service Module installation.
For more information on installation instructions, including silent installation options, see the iDRAC Service Module Installation
Guide.
Limitation
● Do not specify user profile folders such as a desktop folder (C:\Users\administrator\Desktop) as custom
installation paths for installing iDRAC Service Module. This is because services running on the system account cannot access
such folders.
● Lifecycle Controller logs are not seen in the new folder in the Event Viewer (169898) if you have recently changed the folder
name of the Lifecycle Controller logs in the Event Viewer, Microsoft recommends that you reboot the operating system to
be able to view the Lifecycle Controller logs under the new view name (BITS113354).
● On Windows operating system, a feature that is enabled using the installer and disabled using any interface other than the
installer, can only be enabled using the same interface or the installer in GUI mode (BITS180635).
● Feature Lifecycle Log Replication on OS Log shows one-hour difference in the EventTimeStamp displayed in OS log, when
daylight saving is applied. (BITS088419)
● The iDRAC Access via Host OS feature is not supported on VMware ESXi Operating Systems.
● When Local RACADM set is disabled through iDRAC interfaces,
○ The iDRAC Service Module will fail to configure the OS to iDRAC Pass-through in the USB NIC mode.
○ If OS to iDRAC Pass-through in the USB NIC mode is already configured, Watchdog feature does not work resulting in
ASR000 event.
iDRAC Service Module functionality is restored when "Local racadm set" is enabled.
● EventID for Lifecycle Controller Logs replicated to OS log will be 0 for some of the past events.
● TrapID for In-band SNMP Traps will be 0 for some of the past traps.