I am not able to access the iDRAC page through the
host OS after performing an iDRAC factory reset
operation, such as racadm racresetcfg. How do I
troubleshoot the issue?
Ensure that the OS to iDRAC passthru channel is enabled. By default, it is disabled in factory mode. To enable the OS to IDRAC passthru
channel on iDRAC, use the following command, racadm set idrac.os-bmc.adminstate 1.
I am seeing 169.254.0.2 as the source IP address in
the iDRAC SNMP trap received via iSM. How do I
troubleshoot the issue?
On Linux OS, the iDRAC SNMP traps received via Host OS displays the hostname or source IP address as 169.254.0.2 instead of the actual
Host OS name or IP address. This is decided by the OS to populate the entry before rendering the trap to the user.
I have congured OS to iDRAC pass-through to LOM
and when I try to run dcism-sync, the update
operation fails. What can be done?
OS to iDRAC pass-through should be congured to USB-NIC mode. This is a pre-requisite for iDRAC Service Module installation and
update.
When Hyper-V is enabled in the Host OS, iSM is
unable to communicate with iDRAC. What should I
do?
Enable the remote NDIS device under Network Adapter.
I am able to enable or disable the WMIInfo feature of
iSM on Linux and VMware ESXi Operating Systems
using racadm and WSMAN commands. Does this
impact my iSM conguration on the Host OS?
The WMIInfo feature of iSM is applicable only for Microsoft Windows Operating Systems. However, enabling or disabling this feature from
any of the iDRAC interfaces on any Operating System other than Microsoft Windows does not impact the iSM conguration on the Host
OS.