Release Notes

User notes for supported Microsoft Windows operating
systems
To enable WSMAN silently, run the following CLI command:
Msiexec.exe /i iDRACSvcMod.msi ADDLOCAL="WSMAN_Enablement" CP_SELF_SIGN_CERT="2"
CP_WSMAN_PORT="1234" CP_CERTIFICATE="1" CP_NEGOTIATE="1" /qn
.
User notes for supported Red Hat Enterprise Linux and
SUSE Linux Enterprise Server
To perform an Express Install on Red Hat Enterprise Linux and SUSE Linux Enterprise Server operating systems:
Execute dcism-setup.sh -x from the SYSMGMT/iSM/linux directory.
For more information on the installation instructions, including silent installation, see the iDRAC Service Module User's Guide.
You do not have the permissions required to run the script directly on the disk partition. Use the format sh ISM_Lx.sh to run the
script and initiate iDRAC Service Module installation.
Limitations
The Full PowerCycle feature is not supported on FC640, M640, and M640-VRTX platforms.
Limitations on Microsoft Windows and Linux operating systems
JIT-133026
Description: To use the single sign-on feature in iSM, you must upgrade to iSM 3.5.0, and your iDRAC firmware must be version
4.00.00.00 or later.
Limitations on Microsoft Windows operating systems
During iDRAC Service Module installation, do not specify your desktop user profile's folder path in the custom installation path. For
example, C:\Users\administrator\Desktop must not be used in the custom installation path. This is because services running on the
system account cannot access such folders.
You cannot view Lifecycle Controller logs in the new folder in the Event Viewer (169898) if you have recently changed the folder name
of the Lifecycle Controller logs in the Event Viewer. Microsoft recommends that you reboot the operating system to be able to view
the Lifecycle Controller logs under the new view name.
JIT-115250
When iDRAC Service Module is installed on systems running Microsoft Windows operating systems using an OS DUP, then the iSM
Modify and Repair operation from the Add/Remove programs will throw an error, original source path of the file is not found . You can
extract the iSM DUP file, double click the MSI file, and run repair.
Limitations on Linux operating systems
BITS088419
Description: Lifecycle Log Replication feature in operating system log shows one-hour difference in the EventTimeStamp displayed in
operating system log when daylight saving time is in effect.
JIT-87572
Description: When the iDRAC HardReset option is disabled in iDRAC and you can perform a iDRACHardReset operation from the
hypervisor operating systems such as Citrix Xen , the result indicates success although iDRAC is not reset.
4