Release Notes

iDRAC Service Module functionality is restored when Local Racadm set is enabled.
Issue 4
Description: EventID for Lifecycle Controller Logs replicated to OS log will be 0 for some of the past events.
Issue 5
Description: TrapID for In-band SNMP Traps will be 0 for some of the past traps.
Issue 6 (JIT-91716, JIT-90475)
Description: WSMan commands for remote iDRAC Hard Reset and remote Enabling or Disabling of InBandSNMPTraps features
are not functional on VMware ESXi 6.7.
Workaround: Stop and start WBEM in ESXi 6.7 using the following commands:
1. esxcli system wbem set e 0
2. esxcli system wbem set e 1
Issue 7 (JIT-87572)
Description: When iDRAC Hard Reset is disabled in iDRAC and user performs iDRACHardReset from the Hypervisor operating
systems like VMware ESXi, the result indicates success although iDRAC is not reset.
Issue 8 (JIT-101652, JIT-102735, JIT-103063)
Description: While upgrading iDRAC Service Module ESXi Live VIB package through VMware Update Manager (VUM), the host
OS enters maintenance mode and then reboots..
6